Related Experiment Video
Updated: Dec 25, 2025

Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
Pulse transit time as a proxy for vasoconstriction in younger and older adults
Arjen Mol1, Carel G M Meskers2, Sjoerd P Niehof3
1Department of Human Movement Sciences, @AgeAmsterdam, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, Van der Boechorstraat 9, 1081 BT Amsterdam, the Netherlands; Department of Biophysics, Donders Institute for Brain, Cognition and Behaviour, Radboud University, Heijendaalseweg 135, 6525 AJ Nijmegen, the Netherlands.
Objectives:
Changes of vasoconstriction may be measured non-invasively using pulse transit time. This study assessed the sensitivity, test-retest reliability and validity of pulse transit time during vasoconstriction provocation and active standing, and the predictive value of pulse transit time for blood pressure drop.
Methods:
Fifty-five younger (age < 65 years) and 31 older adults (age > 70 years) underwent electrocardiography, wrist and finger photoplethysmography and continuous blood pressure and total peripheral resistance measurements during vasoconstriction provocation using a cold pressor test (21 younger adults), or active stand tests (all other participants). Pulse transit time was defined as the time lag between the electrocardiography R-peak and the peak in the photoplethysmography first derivative; sensitivity as a significant decrease relative to baseline; test-retest reliability as the intra class correlation between different repeats of the same test; validity as the association between peripheral resistance and pulse transit time; predictive value as the association between supine resting pulse transit time and mean arterial pressure drop during active standing.
Results:
Finger pulse transit time was sensitive and reliable (ICC 0.2-0.8) during vasoconstriction provocation, but wrist pulse transit time was poorly reliable (ICC 0-0.5); only finger pulse transit time was sensitive to and reliable (ICC 0.4-0.8) during active standing in both younger and older adults. Finger pulse transit time was not associated with total peripheral resistance. Supine resting pulse transit time had predictive value for blood pressure drop during active standing in older adults (β -0.16; p 0.025).
Conclusions:
Pulse transit time was sensitive to and reliable during vasoconstriction provocation and active standing, but did not significantly differ between younger and older adults. Pulse transit time could not be demonstrated to particularly reflect vasoconstriction, but it had predictive value for blood pressure drop during active standing.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pharmacodynamics in Geriatric Patients: Effects of Age
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Absorption
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...