Related Experiment Video
Updated: Dec 24, 2025

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Changes in CO-oximetry values and pulse oximetry in isoflurane-anesthetized dogs with and without nitrous oxide
Teela Jones1, Cindy Feng1, Tanya Duke-Novakovski1
1Department of Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5B4 (Jones, Duke-Novakovski); School of Public Health, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5B4 (Feng).
Abstract:
Concentrations of 64% to 70% nitrous oxide (N2O) provide intra-operative analgesia. Clinically, pulse oximeter estimation (SpO2) of oxygen (O2) hemoglobin saturation (SaO2) was observed to decrease with N2O. Absorption atelectasis from breathing O2 was thought to decrease arterial partial pressure of O2 (PaO2) below 70 mmHg and reduce SaO2 and SpO2 when N2O was used. Administering N2O from the beginning of the anesthesia might prevent atelectasis development and low PaO2. The study was done in 2 parts (P < 0.05). In Part 1, isoflurane-anesthetized dogs undergoing ovariohysterectomy (n = 15 each group) breathed N2O from anesthesia start (N2Oearly) or 1 hour later (N2Olate). SpO2, CO-oximetry values, and PaO2 were compared to dogs breathing O2 throughout anesthesia (control). Timing of N2O introduction did not affect PaO2 (lowest = 94 mmHg), SaO2, or SpO2. With N2O, the lowest SpO2 value was 91% and corresponded to a PaO2 of 151 mmHg. Carboxyhemoglobin increased (highest = 2.7%) and SaO2 decreased with N2O (lowest = 96.7%). In Part 2, to replicate findings, 10 isoflurane-anesthetized dogs breathed N2O, then O2. With N2O, SaO2 did not decrease, but carboxyhemoglobin increased and returned to baseline once N2O was discontinued. The dog with the highest carboxyhemoglobin (2%) had an SaO2 of 96.8% (PaO2 = 93 mmHg). Carboxyhemoglobin and SaO2 changes were not clinically significant. Pulse oximetry did not reliably estimate SaO2 but N2O was not always a factor.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Inhalational Anesthetics: Overview
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...