Related Experiment Video
Updated: Dec 24, 2025

Automated Microfluidic Blood Lysis Protocol for Enrichment of Circulating Nucleated Cells
Published on: December 31, 2009
Nanotopography as a trigger for the microscale, autogenous and passive lysis of erythrocytes
Vy T H Pham1, Vi Khanh Truong, David E Mainwaring
1Department of Chemistry and Biotechnology, School of Science, Faculty of Science, Engineering and Technology, Swinburne University of Technology, PO BOX 218, Hawthorn, Victoria 3122, Australia. eivanova@swin.edu.au.
Abstract:
Microscale devices are increasingly being developed for diagnostic analysis although conventional lysis as an initial step presents limitations due to its scale or complexity. Here, we detail the physical response of erythrocytes to the surface nanoarchitecture of black Si (bSi) and foreshadow their potential in microanalysis. The physical interaction brought about by the spatial convergence of the two topologies: (a) the nanopillar array present on the bSi and (b) the erythrocyte cytoskeleton present on the red blood cells (RBCs), provides spontaneous stress-induced cell deformation, rupture and passive lysis within an elapsed time of ∼3 min from immobilisation to rupture and without external chemical or mechanical intervention. The mechano-responsive bSi surface provides highly active yet autogenous RBC lysis and a prospect as a front-end platform technology in evolving micro-fluidic platforms for cellular analyses.