Related Experiment Video
Updated: Dec 24, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Nickel-gold bimetallic monolayer colloidal crystals fabricated via galvanic replacement as a highly sensitive
Bebeto Lay1, Victoria E Coyle, Ahmad Esmaielzadeh Kandjani
1Centre for Advanced Materials and Industrial Chemistry (CAMIC), School of Applied Sciences, RMIT University, GPO Box 2476 V, Melbourne, Victoria 3001, Australia. ahmad.kandjani@rmit.edu.au suresh.bhargava@rmit.edu.au.
Abstract:
Bimetallic Ni-Au monolayer colloidal crystals (MCCs) were fabricated by galvanic replacement of Ni monolayers with Au salt. The influence of Au concentration used in the galvanic replacement solutions on the morphology and structure of the resulting Ni-Au surface is studied. It was found that the use of monolayer colloidal crystals, which display cohesive structure formations across the monolayer, results in the galvanic replacement reaction occurring more evenly over the surface when compared to the thin film counterpart. The fabricated devices were analyzed under alkaline conditions using chronoamperometric techniques to detect glucose concentrations ranging between 20 μM and 10 mM. The optimum Ni-Au MCC substrate was produced using 0.1 mM Au salt solution and showed a very low experimental detection limit of 14.9 μM and a calculated sensitivity of 506 μA mM-1 cm-2, which was ∼3 times larger than that of the plain Ni MCC substrate. The Ni-Au MCC substrate also showed minimal current response changes in the presence of common physiological contaminants, thus being a highly selective electrochemical glucose sensor.
More Related Videos
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
12:20Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
Published on: July 22, 2013