Influence of cavity depth and restoration of non-carious cervical root lesions on strain distribution from various
Je-Kang Du1,2, Ju-Hui Wu2,3, Ping-Ho Chen1
1School of Dentistry, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, San-Ming, District, Kaohsiung, 807, Taiwan.
Background:
We aimed to investigate the load-induced strain variation in teeth with unrestored and resin-based composite restored non-carious cervical lesions (NCCLs).
Methods:
Twelve extracted premolars were provided for measuring buccal-side root NCCLs. Strain gauges were fixed at four measuring sites of each tooth, two at the buccal surface and two at the lingual surface. NCCLs were prepared with occlusal margins at the cemento-enamel junction. A static 9-kg load was applied at seven occlusal loading points: buccal cusp tip (BC), inner inclination of the BC, lingual cusp tip (LC), inner inclination of the LC, center of the mesial marginal ridge or distal marginal ridge, and center of the central groove. The strain was detected at each site in teeth with NCCL depths of 0 (control), 0.5, 1.0, and 1.5 mm. Each NCCL was restored using an adhesive composite resin, and the strains were re-measured.
Results:
The strains at the NCCL occlusal and gingival margins decreased with increasing defect depths, and the effect was significant when the depth of the defect was 1.5 mm. Loading on the buccal and lingual cusps induced prominent strain variation. The strains at all depth distribution recovered to nearly intact conditions when the NCCLs were restored.
Conclusions:
NCCLs at 1.5 mm depth are detrimental, but they can be restored using resin composites.
Clinical Significance:
The existence of NCCLs should not be ignored. The depth of the NCCL may affect the progression of the lesion. Resin composite restoration is an appropriate method for preventing persistent NCCL deterioration.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Normal Strain under Axial Loading
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Residual Stresses in Bending
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...