Background:
Dissolution of artemether (ART) and lumefantrine (LUM) active pharmaceutical ingredients (APIs) in fixed dose combination (FDC) ART/LUM tablets is one of the critical quality attributes. Thus, the verification of the release profile of ART and LUM from FDC ART/LUM tablets using a robust and discriminatory dissolution method is crucial. Therefore, the aim of this study was to develop and validate an appropriate dissolution method for quality control of FDC ART/LUM tablets.
Methods:
The dissolution medium was selected based on saturation solubility data and sink conditions. The effect of agitation speed, pH and surfactant concentration on the release of ART and LUM was evaluated by employing a two-level factorial experiment. The resulting final method was validated for linearity, precision, robustness and API stability. In addition, the discriminatory power of the method was evaluated using expired and unexpired FDC ART/LUM products.
Results:
A suitable dissolution profile of FDC ART/LUM tablets was obtained in 900 ml HCl (0.025 N, pH 1.6) with 1%Myrj 52 using paddle method at 100 rpm and 37 °C. ART and LUM were analysed using a HPLC method with UV detection at wavelengths of 210 and 335 nm, respectively. The results from the stability study showed that ART and LUM were sufficiently stable in HCl (0.025 N, pH 1.6) with 1%Myrj 52 at 37 °C. The method was linear (r2 = 0.999) over the concentration range of 6.25-100 μg/ml. The results for precision were within the acceptance limit (%RSD < 2). The percent relative standard deviation (< 2%) and statistically non-significant (p > 0.05) difference in release of ART and LUM observed between deliberately changed dissolution method settings (pH = 1.6 ± 0.2 or agitation speed = 100 ± 2) and optimized dissolution conditions revealed the robustness of the dissolution method. The method was capable to discriminate among different FDC ART/LUM products with different quality.
Conclusions:
The developed dissolution method is robust and discriminatory. It can be used in the quality evaluation of FDC ART/LUM tablets.
More Related Videos
06:14Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients
Published on: October 15, 2017
09:59Coherent anti-Stokes Raman Scattering CARS Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
Related Concept Videos
In Vitro Drug Dissolution: Alternative Methods
Drug Dissolution: Requirements and Profile Comparison
In Vitro Drug Dissolution: Compendial Testing Models I
Factors Affecting Dissolution: Particle Size and Effective Surface Area
In Vitro Drug Dissolution: Compendial Testing Models II
Factors Influencing Drug Absorption: Pharmaceutical Parameters