Analysis of electrocautery smoke released from the tissues frequently cut in orthopedic surgeries
Ali Yeganeh1, Mikaiel Hajializade1, Alireza Pahlevan Sabagh1
1Department of Orthopaedics Surgery, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran 1445613131, Iran.
Background:
Electrosurgical smoke could be different by the device of cutting or the type of tissue that is being cut.
Aim:
To analyze the electrocautery smoke released from the tissues that are frequently cut in orthopedic surgeries.
Methods:
The released smoke from electrocautery of five different tissue types (meniscus, ligament, adipose, muscle, and synovium) of five patients who underwent total knee arthroplasty were collected and analyzed for volatile organic compounds (VOCs) and 27 candidate polycyclic aromatic hydrocarbons (n = 25). Surgical smoke was produced with an electrocautery device for 4 min.
Results:
None of the 27 evaluated polycyclic aromatic hydrocarbons compounds were detectable in electrocautery smoke collected from the surgical cutting of the different tissues. The number and identity of detected VOCs were similar between the patients but not between tissue types. The number of detected VOCs was the highest in synovial tissue (n = 21) and the lowest in the meniscus and adipose tissue (n = 12). The number of toxic and/or carcinogenic VOCs were the most in the muscle and meniscus tissues (Toluene, Ethylbenzene, and Styrene). No toxic and/or carcinogenic VOCs were identified in the ligament and adipose tissue.
Conclusion:
Meniscus and muscle tissue are associated with the highest number of toxic and/or carcinogenic VOCs. Therefore, we recommend that surgeons avoiding the electrocautery of these tissues.
More Related Videos
09:01A Technique for Subcutaneous Abdominal Adipose Tissue Biopsy via a Non-diathermy Method
Published on: September 30, 2017
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Atomic Emission Spectroscopy: Interference