Related Experiment Video
Updated: Dec 24, 2025

Measurement of Greenhouse Gas Flux from Agricultural Soils Using Static Chambers
Published on: August 3, 2014
Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural
Jihong Wang1,2, Tengfei Zhang1, Shugang Wang1
1School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian 116024, China.
Abstract:
Natural ventilation is an effective strategy to control thermal comfort in buildings, and can be enhanced depending on the window style. The combination of natural ventilation and window can also facilitate the removal or dilution of gaseous pollutants from indoor sources in newly decorated buildings. However, the windows on the same facade may cause gaseous pollutant cross-transmission during single-sided natural ventilation between households on different floors close to the source. Although some research has focused on the pollutant cross-transmission in buildings, the simplification of windows into rectangular openings often affects accurate knowledge of pollutant transmission characteristics. Therefore, this investigation explored gaseous pollutant cross-transmission through real windows during single-sided, buoyancy-driven ventilation in a multistory building. Six types of windows were modeled for the indoor pollutant of gaseous formaldehyde (HCHO). Computational fluid dynamics (CFD) was utilized to solve characteristics of pollutant transmission inside and outside the multistory building. The results indicated that the ventilation rates, thermal profiles and pollutant transmission inside and outside the building varied for each window type, although the open window areas were identical. The re-entry ratio of exhausted air entering upper floors and the infection risk of epidemic viruses caused by airborne cross-transmission was sensitive to ventilation rates and window configurations, while the sensitivities for window configurations varied case by case. The comparisons also revealed that the specification of ambient temperature and pollutant release rate ultimately did not affect the evaluation of pollutant cross-transmission using CFD.
More Related Videos
08:18Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
09:03Assessment of Methane and Nitrous Oxide Fluxes from Paddy Field by Means of Static Closed Chambers Maintaining Plants Within Headspace
Published on: September 6, 2018
Related Concept Videos
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Physical Principles Governing Gas Exchange
Gas Laws Governing Respiration
The behavior of gases is guided by Dalton's Law of partial pressures and Henry's Law.
Dalton's Law asserts that the total...
External and Internal Respiration
Gas Exchange and Transport
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...