Related Experiment Video
Updated: Dec 23, 2025

Author Spotlight: Investigating the Key Factors of Obliterative Bronchiolitis After Lung Transplantation
Published on: November 10, 2023
[Predictive factors for failure of continuous positive airway pressure treatment in infants with bronchiolitis]
1Department of Respiratory Medicine, Children's Hospital of Chongqing Medical University/Ministry of Education Key Laboratory of Child Development and Disorders/National Clinical Research Center for Child Health and Disorders/China International Science and Technology Cooperation Base of Child Development and Critical Disorders/Chongqing Key Laboratory of Pediatrics, Chongqing 400014, China. luozhengxiu816@163.com.
Insights
Predictors of continuous positive airway pressure (CPAP) failure in infants with bronchiolitis include poor oxygenation, high Pediatric Risk of Mortality III (PRISM III) scores, atelectasis, and cardiac insufficiency. These factors aid in identifying infants at risk for CPAP treatment failure.
Area of Science:
- Pediatrics
- Respiratory Medicine
- Critical Care
Background:
- Bronchiolitis is a common respiratory infection in infants.
- Continuous positive airway pressure (CPAP) is a key treatment for respiratory distress in infants with bronchiolitis.
- Identifying factors predicting CPAP failure is crucial for timely intervention.
Purpose of the Study:
- To identify predictive factors for the failure of CPAP treatment in infants diagnosed with bronchiolitis.
- To analyze clinical data to understand outcomes of CPAP therapy.
Main Methods:
- Retrospective analysis of clinical data from 310 infants (1-12 months) with bronchiolitis treated with CPAP.
- Comparison of clinical features between successful (270 cases) and failed (40 cases) CPAP treatment groups.
- Multivariate logistic regression analysis to determine predictive factors for CPAP failure.
Main Results:
- Pediatric Risk of Mortality III (PRISM III) score ≥10 (OR=13.905), atelectasis (OR=12.080), cardiac insufficiency (OR=7.741), and lack of oxygenation improvement (P/F ratio <203) after 2 hours (OR=34.084) predicted CPAP failure.
- Lack of P/F improvement had an AUC of 0.793, sensitivity of 70.3%, and specificity of 82.4% for predicting failure.
Conclusions:
- Lack of P/F improvement within 2 hours, PRISM III score ≥10, atelectasis, and cardiac insufficiency are significant predictors of CPAP treatment failure in infants with bronchiolitis.
- These factors can guide clinical decisions and resource allocation for managing infants with bronchiolitis requiring CPAP.
Objective:
To study the predictive factors for the failure of continuous positive airway pressure (CPAP) treatment in infants with bronchiolitis.
Methods:
A retrospective analysis was performed on the clinical data of 310 hospitalized children (aged 1-12 months) with bronchiolitis treated with CPAP. Their clinical features were compared between the successful treatment group (270 cases) and the failed treatment group (40 cases). A multivariate logistic regression analysis was used to explore the predictive factors for failure of CPAP treatment.
Results:
The multivariate logistic regression analysis showed that the score of the Pediatric Risk of Mortality III (PRISM III) ≥10 (OR=13.905), development of atelectasis (OR=12.080), comorbidity of cardiac insufficiency (OR=7.741), and no improvement in oxygenation index (arterial partial pressure of oxygen/fraction of inhaled oxygen, P/F) after 2 hours of CPAP treatment (OR=34.084) were predictive factors for failure of CPAP treatment for bronchiolitis (P<0.05). In predicting CPAP treatment failure, no improvement in P/F after 2 hours of CPAP treatment had an area under the receiver operating characteristic curve of 0.793, with a sensitivity of 70.3% and a specificity of 82.4% at a cut-off value of 203.
Conclusions:
No improvement in P/F after 2 hours of CPAP treatment, PRISM III score ≥10, development of atelectasis, and comorbidity of cardiac insufficiency can be used as predictive factors for CPAP treatment failure in infants with bronchiolitis.
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-III
Pulmonary Cycle: Exhalation
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
