Purpose:
This biomechanical study compared fixation constructs used in radioscapholunate (RSL) arthrodesis. We hypothesized that plates and screws, pin plate, and headless screws would all provide similarly stable fixation constructs.
Methods:
We chose 27 fresh-frozen cadaveric extremities, 14 of which were matched pairs and randomized them into 3 groups to match age, body mass index, and sex. An RSL arthrodesis was simulated with plates and screws, pin plates, or headless compression screws via a standard dorsal approach to the wrist. Specimens were mounted into a custom jig and cycled through an arc of 120° for 5,000 cycles to simulate 6 weeks range of motion (ROM). A 9-mm stroke differential variable reluctance transducer recorded continuous displacement, and gross hardware failure in the form of screw or pin cutout was investigated after the simulation.
Results:
Greater distraction across the RSL articulation was observed in the headless screws compared with the plate-and-screws and pin-plate constructs, with no difference between the plates and screws and pin plates. Greater average displacement was observed in the headless screws compared with the plate-and-screws and pin-plate constructs, with no difference between the pin plates and plates and screws. Gross hardware failure was observed least in plates and screws followed by pin plates.
Conclusions:
Plate-and-screw and pin-plate constructs are biomechanically superior in resisting RSL distraction compared with headless compression screws for RSL arthrodesis over 6 weeks of simulated ROM in the absence of healing.
Clinical Relevance:
The results of this study demonstrated negligible arthrodesis site distraction in the plate-and-screws and pin-plate constructs when 6 weeks of ROM was simulated. When translated to a clinical scenario, these findings may allow earlier discontinuation of external immobilization after surgery.