Related Experiment Video
Updated: Dec 23, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Custom-Fit Three-Dimensional-Printed BiPAP Mask to Improve Compliance in Patients Requiring Long-Term Noninvasive
Ying Ying Wu1, Deepshikha Acharya2, Camilla Xu1
1Department of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213
Abstract:
Noninvasive ventilator support using bi-level positive airway pressure/continuous positive airway pressure (BiPAP/CPAP) is commonly utilized for chronic medical conditions like sleep apnea and neuromuscular disorders like amyotrophic lateral sclerosis (ALS) that lead to weakness of respiratory muscles. Generic masks come in standard sizes and are often perceived by patients as being uncomfortable, ill-fitting, and leaky. A significant number of patients are unable to tolerate the masks and eventually stop using their devices. The goal of this project is to develop custom-fit masks to increase comfort, decrease air leakage, and thereby improve patient compliance. A single-patient case study of a patient with variant ALS was performed to evaluate the custom-fit masks. His high nose bridge and overbite of lower jaw caused poor fit with generic masks, and he was noncompliant with his machine. Using desktop Stereolithography three-dimensional (3D) printing and magnetic resonance imaging (MRI) data, a generic mask was extended with a rigid interface such that it was complementary to the patient's unique facial contours. Patient or clinicians interactively select a desired mask shape using a newly developed computer program. Subsequently, a compliant silicone layer was applied to the rigid interface. Ten different custom-fit mask designs were made using computer-aided design software. Patient evaluated the comfort, extent of leakage, and satisfaction of each mask via a questionnaire. All custom-fit masks were rated higher than the standard mask except for two. Our results suggest that modifying generic masks with a 3D-printed custom-fit interface is a promising strategy to improve compliance with BiPAP/CPAP machines.
More Related Videos
06:21Design and Development of a Three-Dimensionally Printed Microscope Mask Alignment Adapter for the Fabrication of Multilayer Microfluidic Devices
Published on: January 25, 2021
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings