Updated: Dec 23, 2025

Determining Pain Detection and Tolerance Thresholds Using an Integrated, Multi-Modal Pain Task Battery
Published on: April 14, 2016
Comparable conditioned pain modulation and augmented blood pressure responses to cold pressor test among resistance
Masataka Umeda1, Akiko Okifuji2
1Department of Kinesiology, University of Texas at San Antonio, San Antonio, TX, USA.
Abstract:
Conditioned pain modulation (CPM) test examines central pain inhibitory processing. Aerobically-trained individuals show greater CPM. However, there is a paucity of knowledge regarding CPM among resistance exercise-trained individuals, although regular engagement in resistance exercise may lead to greater CPM via augmented blood pressure (BP) responses during the CPM test. Therefore, the present study compared CPM and BP responses between resistance exercisers (REs) and controls (n = 15 per group). The participants completed the CPM test to evaluate changes in electrical pain ratings to the ankle after cold pressor test (CPT) consisting of immersing a hand into a cold water bath compared to baseline. REs and controls exhibited similar CPM, although REs showed greater systolic BP responses to CPT compared to controls. The results suggest that the role of BP in CPM is likely complex, and the role of exercise in central pain processing and cardiovascular system needs to be studied.
Related Concept Videos
Measurement of Blood Pressure
Responses to Heat and Cold Stress
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Hypertension and Regulation of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...