Related Experiment Video
Updated: Dec 22, 2025

Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021
Infections Associated with Resterilized Pacemakers and Defibrillators
Thomas F Khairy1, Marie-Andrée Lupien1, Santiago Nava1
1From the Montreal Heart Institute, Université de Montréal, Montreal (T.F.K., M.-A.L., C.V., R.C., D.R., M.T., M.D., B.T., P.G.G., L.R., K.D., B.M., R.T., J.C.-T., L.M., P.K.); Instituto Nacional de Cardiologia, Ignacio Chavez, Mexico City (S.N.); the Dominican Institute of Cardiology, Santo Domingo, Dominican Republic (F.V.B.); Clínicas Médicas las Américas, Guatemala City, Guatemala (F.S.O.); and Cardiología Hospital General del Sur, Choluteca (N.E.L.O.), and Instituto Nacional Cardiopulmonar (G.S.M.) and Medicina Interna-Programación de Marcapaso Definitivo, Instituto Nacional Cardiopulmonar, Tegucigalpa (C.A.C.) - all in Honduras.
Background:
Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern.
Methods:
A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk.
Results:
Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis.
Conclusions:
Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
08:25Visualization of Streptococcus pneumoniae within Cardiac Microlesions and Subsequent Cardiac Remodeling
Published on: April 7, 2015
Related Concept Videos
Endocarditis I: Introduction
Endocarditis IV: Nursing Management
Endocarditis III: Medical Management
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Mitral Stenosis III: Medical Management
Bacterial Signaling