Randomized multicenter study on long-term complications of peripherally inserted central catheters positioned by
Yu-Xia Yin1,2, Wei Gao3, Xu-Ying Li4
1Department of Vascular & Intervention, Tenth Peoples' Hospital of Tongji University, Shanghai, China.
Background:
The intracavitary electrocardiogram (IC-ECG) method has been used for the tip location of central venous access devices for the advantage of being safe, accurate and highly cost effective. However, long-term follow-up is rare. This randomized clinical trial aimed to evaluate the long-term complications of peripherally inserted central catheters (PICCs) positioned by the IC-ECG method.
Methods:
We randomized 2250 patients who needed PICC placement to either a landmark length estimation supplemented by IC-ECG positioned group (ECG group) or the traditional landmark length estimation alone group (control group) in a 2:1 allocation. Post-procedural chest X-rays were applied to confirm tip position. Follow-up was performed monthly to six months. Standard statistics analyses were performed with the SAS 9.13 software, and p < 0.05 was considered significant.
Results:
As evaluated by post-procedural chest X-ray, tip location in the ECG group had a first-attempt success (catheter tip located at optimal position) of 91.7% (95% confidence interval (CI): 90.3%-93.1%), significantly higher than 78.9% (95% CI: 76.0%-81.9%) observed in the control group (p < 0.001). At six-month follow-up, in the control group, frequency of total complications was 9.5%, including the exit site infection (4.0%), phlebitis (1.3%), deep venous thrombosis (1.5%), liquid extravasation (2.9%) and mechanical failure (1.9%). The IC-ECG group had significantly lower rates of complications (6.4%, p < 0.001), including the exit site infection (2.7%, p > 0.05), phlebitis (1.1%, p > 0.05), deep venous thrombosis (1.2%, p > 0.05), liquid extravasation (2.4%, p > 0.05) and mechanical failure (1.2%, p > 0.05). In the univariable logistic regression analysis, ECG method, other diseases and upper arms were the independent protective factors, and the number of adjustment procedures (n ≥ 2) were the independent risk factors of the complications.
Conclusions:
The intra-procedural tip location by IC-ECG is more safe and accurate than the traditional method of verifying tip location only post-procedurally, by chest X-ray.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization III: Left Heart Catheterization
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Cardiac Catheterization II: Right Heart Catheterization
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...