Related Experiment Video
Updated: Dec 22, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
High-Score US-Suspicious Subcentimeter Thyroid Nodules: What Factors Affect Adequate Sampling of US-Guided
Yang Li1, Jin Hong Yu2, Ping Jie Du1
1Department of Radiology, The Affiliated Hospital of North Sichuan Medical College, 63 Wenhua Road, Nanchong 637000, Sichuan, China.
Background:
Fine-needle aspiration biopsy (FNAB) is diagnostic standard for thyroid nodules. However, the influence of adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules is not known well.
Objectives:
To assess the factors affecting adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules.
Methods:
Three hundred and forty-nine consecutive US-guided FNAB procedures were performed in 344 patients with subcentimeter thyroid nodules. The adequate sample rate was analyzed for all nodules on the basis of nodule-related and technical factors. The factors affecting adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules were determined by multivariate logistic regression.
Results:
The adequate sample rate increased with larger nodules (72.7% for 3-6 mm nodules and 84.9% for 7-10 mm nodules (P=0.007)). The adequate sample rate was 63.9%, 81.3%, and 90.6% in nodules with macrocalcifcation, microcalcification, and no calcification, respectively (P < 0.001). The adequate sample rate was 71.8% for biopsies performed with a perpendicular needle path and 85.0% with a parallel needle path (P=0.004). The significant factors affecting adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules were nodule size (P < 0.001; odds ratio (OR) for 7-10 mm nodules was approximately 3.0 times higher than that for 3-6 mm nodules), calcification (P < 0.001; OR for nodules without calcification was approximately 5.3 times higher than that for the nodules with macrocalcification), and needle path (P=0.044; OR for the use of the parallel needle path was about 1.8 times higher than that for the perpendicular needle path).
Conclusion:
Nodule size, calcification, and needle path were the determinants of sample adequacy. The adequate sample rate was higher in larger nodules, in nodules without calcification, and upon using a parallel needle path for biopsy.