Related Experiment Video
Updated: Dec 22, 2025

Double-Staining Method to Detect Pectin in Plant-Fungus Interaction
Published on: February 4, 2022
Ultrasound for pectinase modification: an investigation into potential mechanisms
Xiaobin Ma1, Jingwen Cai2, Donghong Liu1,3
1College of Biosystems Engineering and Food Science, National-Local Joint Engineering Laboratory of Intelligent Food Technology and Equipment, Zhejiang Key Laboratory for Agro-Food Processing, Zhejiang R & D Center for Food Technology and Equipment, Zhejiang University, Hangzhou, China.
Background:
Today, ultrasound is increasingly utilized in enzyme modification. Strongly dependent on the specific operational conditions, the modification effect brought by ultrasound can be activation and inactivation of enzymes. This work aims to study the ultrasound mechanisms under different conditions, to investigate the respective roles of free radical effect and mechanical effect in pectinase activation and inactivation, and to reveal the influence of pectinase concentration on the ultrasound-modification effect.
Results:
When ultrasound was introduced to a liquid system, generation of free radicals was positively correlated with ultrasound intensity and treatment duration, but negatively correlated with temperature. Thiourea with a concentration of 4 mmol L-1 was selected as a free radical scavenger to effectively shield ultrasound free radicals. The highest enzyme activity of pectinase solutions at 0.1, 1.0, and 10.0 mg mL-1 was obtained at the same ultrasound intensity of 4.50 W mL-1 and time of 15 min, where the enzyme activity was increased by 68.24%, 20.98% and 18.83%, respectively. Furthermore, the addition of thiourea enhanced the enzyme activity at each tested ultrasound intensity and time, especially those exceeding the best conditions; it also eliminated the redshift phenomenon that was previously presented in the fluorescence spectra of pectinase samples.
Conclusion:
Pectinase concentrations did not change the optimum ultrasound conditions for enzyme modification, but pectinase with a low concentration was more vulnerable to ultrasound treatment. During modification, ultrasound mechanical effects dominated in the pectinase activation, while free radical effects dominated in the inactivation process. © 2020 Society of Chemical Industry.
More Related Videos
08:51Utilizing the Ethylene-releasing Compound, 2-Chloroethylphosphonic Acid, as a Tool to Study Ethylene Response in Bacteria
Published on: November 10, 2016
09:26Experimental Screening Protocols, Immunocytochemistry and Microscopy-based Imaging Techniques for Penium margaritaceum
Published on: March 28, 2025
Related Concept Videos
Cellulose and Pectic Polysaccharides
As a cell matures, its cell wall specializes according to its type. For example, the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...