Signal Drift in Liquid Chromatography Tandem Mass Spectrometry and Its Internal Standard Calibration Strategy for
Fulin Jiang1, Qian Liu1, Qiaoxi Li1
1Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou 510080, China.
Abstract:
The present project studied the signal drift in liquid chromatography tandem mass spectrometry (LC-MS/MS) and proposed a strategy for compensating such drift. In the study, four 4-component groups were repeatedly run on different LC-MS/MS systems for over 12 h to investigate the dependence of signal drift on time and hardware systems. The 4-component groups each consisted of (1) an analyte, (2) a stable isotope labeled analyte, (3) a compound with similar structure to the analyte, and (4) a compound with dissimilar structure. All of the species showed significant signal drift, generally more than 25% over 12 h. The analyte and its stable isotope labeled analog always have the same drifting pattern including the trends and direction from one LC-MS/MS system to another. Signal drift was also found to be concentration dependent. Our experiments further proved that a conventional stable isotope labeled internal standard in LC-MS/MS quantification would not compensate the variations caused by concentration-dependent signal drift. An ideal internal standard for LC-MS/MS has both identical structure and similar concentration to the analyte. For that, we proposed a new internal standard strategy, pseudo internal standard (Pseudo IS), for LC-MS/MS quantification. Pseudo IS could effectively compensate signal drift in spite of its significant time, system, and concentration dependencies.
More Related Videos
08:03A Tandem Liquid Chromatography–Mass Spectrometry-based Approach for Metabolite Analysis of Staphylococcus aureus
Published on: March 28, 2017
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Related Concept Videos
Tandem Mass Spectrometry
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
High-Performance Liquid Chromatography: Instrumentation
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...