Application of automatic detection based on overnight airflow and blood oxygen in patients with sleep disordered
Jingjing Huang1, Liujie Ren1,2, Lifen Chen3
1ENT Institute, Eye and ENT Hospital of Fudan University, Fenyang Road No. 83, Xuhui District, Shanghai, China.
Purpose:
To explore the feasibility of automatic detection based on air flow and blood oxygen in patients with sleep disordered breathing.
Methods:
This study proposes a new automated detection method for sleep disordered breathing based on overnight airflow and blood oxygen saturation (SaO2). In this regard, local range (LR) of the airflow was adopted to detect apnea events and the SaO2 sudden drops were used to help determine hypopnea events. Pearson correlation index was used to evaluate the relationship between the two automated methods (this study vs. Remlogic software) and the manual reports. Error and mean absolute error (MAE) were used to assess the two automated methods.
Results:
For all patients, the apnea-hypopnea index (AHI), apnea index (AI) and hypopnea index (HI) for our automated scoring and manual reports were highly correlated (the Pearson correlation index were 0.996, 0.995 and 0.928, respectively, P < 0.001). However, HI for Remlogic automated scoring and clinical manual reports was poorly correlated (r = 0.316, P < 0.001). Compared with the manual reports, mean absolute error of AHI, AI and HI between the two automated methods (this study vs. Remlogic software) were statistically significant (P < 0.0001). Furthermore, among the three subgroups (group 1, AHI < 15/h, group 2, 15/h ≤ AHI < 30/h and group 3, AHI ≥ 30/h), the mean error and MAE of AHI between the two automated methods were also statistically significant (P < 0.01).
Conclusions:
Generally, good agreements were shown between our automated detection and clinical reports. This procedure is robust and effective, which would significantly shorten the analysis time.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...