Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
High-speed 1D Raman analyzer for temperature and major species measurements in a combustion environment
Abstract:
In this Letter, we demonstrate a 5 kHz 1D Raman instrument for temporally and spatially resolved quantitative measurements of temperature and all the major species (N2, O2, H2, and H2O) concentration in H2-air flames. The major constituents of the system are a pulse-burst laser operated at 5 kHz and four back-illuminated CCD cameras operated in subframe burst-gating mode. The use of CCD cameras allows achieving a high sampling rate with no compromise on instrument precision, but it requires one camera for each species of interest. A cascade of dichroic mirrors and bandpass filters spectrally separates the Raman signal associated with each of the four species and directs it to a separate camera. Measurements in a well-characterized H2-air premixed flat flame show that the system has precision comparable with the low-speed Raman system. The measuring uncertainty of the species mole fraction ranges between 1% (N2) and 3∼4% (O2 in lean flames). Measurements in laminar and turbulent H2/N2 jet flames show good agreement with the theoretical prediction. By measuring all species simultaneously, important combustion quantities such as the mixture fraction are also derived.
More Related Videos
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
09:57Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Gas Chromatography: Types of Detectors-II