Related Experiment Video
Updated: Dec 21, 2025

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Machine learning based strategy surpasses the traditional method for selecting the first trial Lens parameters for
Yuzhuo Fan1, Zekuan Yu2, Zisu Peng1
1Department of Ophthalmology & Clinical Center of Optometry, Peking University People's Hospital, Beijing 100044, China; College of Optometry, Peking University Health Science Center, Beijing, China; Eye Disease and Optometry Institute, Peking University People's Hospital, China; Beijing Key Laboratory of Diagnosis and Therapy of Retinal and Choroid Diseases, China.
Purpose:
Return zone depth (RZD) and landing zone angle (LZA) are important parameters of corneal refractive therapy (CRT) lenses. A new machine learning algorithm is proposed for prescribing CRT lens parameters in Chinese adolescents with myopia.
Methods:
This is a retrospective study. In total, 1037 Chinese adolescents with myopia (1037 right eyes) were enrolled. A calculation model based on corneal elevation maps was constructed to calculate RZD and LZA for the four quadrants. Furthermore, multiple linear regression and optimized machine learning models were established to predict RZD and LZA values for different combinations of age, sex, and ocular parameters. The four methods (sliding card, linear regression, calculation and optimized machine learning) were then compared to the parameters of the final ordered lens.
Results:
The optimized machine learning pipeline achieved the best performance. Age, sex, horizontal visible iris diameter (HVID), spherical equivalent refraction degree (SER), eccentricity (e), keratometric (K) readings, corneal astigmatism (CA), axial length (AL), AL/corneal curvature ratio (AL/MK), and anterior chamber depth (ACD) were significant to the machine learning model. The R values for the nasal, temporal, superior and inferior LZA based on machine learning were 0.843, 0.693, 0.866 and 0.762, respectively, and those for the RZD were 0.970, 0.964, 0.975 and 0.964, respectively.
Conclusions:
The feasibility and efficiency of an optimized machine learning method to predict LZA and RZD parameters has been demonstrated. The advantage of the proposed method is that it is more accurate, easier to use and faster to implement than the traditional sliding card method.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...