AutoPEWS: Automating Pediatric Early Warning Score Calculation Improves Accuracy Without Sacrificing Predictive
Justin M Lockwood1, Jacob Thomas2, Sara Martin3
1University of Colorado School of Medicine, Department of Pediatrics, Section of Hospital Medicine, Aurora, Colo.
Introduction:
Pediatric early warning scores (PEWS) identify hospitalized children at risk for deterioration. Manual calculation is prone to human error. Electronic health records (EHRs) enable automated calculation, removing human error. This study's objective was to compare the accuracy of automated EHR-based PEWS calculation (AutoPEWS) to manual calculation and evaluate the non-inferiority of AutoPEWS in predicting deterioration.
Methods:
We performed a retrospective cohort study inclusive of non-intensive care unit inpatients at a freestanding children's hospital over 4.5 months in Fall 2018. AutoPEWS mapped the historical manual PEWS scoring rubric to frequently used EHR documentation. We determined accuracy by comparing the expected respiratory subset score based on the current respiratory rate to the actual respiratory score of AutoPEWS and the manual PEWS. The agreement was determined using kappa statistics. We used predicted probabilities from a generalized linear mixed model to calculate areas under the curve for each combination of scores (AutoPEWS, manual) and deterioration outcome (rapid response team activation, unplanned intensive care unit transfer, critical deterioration event). We compared the adjusted difference in areas under the curves between the scores. Non-inferiority was defined as a difference of <0.05.
Results:
There were 23,514 total PEWS representative of 5,384 patients. AutoPEWS respiratory scores were 99.97% accurate, while the manual PEWS respiratory scores were 86% accurate. AutoPEWS were higher overall than the manual PEWS (mean 0.65 versus 0.34). They showed a fair-to-good agreement (weighted kappa 0.42). Non-inferiority of AutoPEWS compared with the manual PEWS was demonstrated for all deterioration outcomes.
Conclusions:
Automation of PEWS calculation improved accuracy without sacrificing predictive ability.
More Related Videos
07:31Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
04:54Author Spotlight: IntelliSleepScorer — A High-Accuracy, Accessible GUI Software for Automated Sleep Stage Scoring in Mice and its Application in Psychiatric Research
Published on: November 8, 2024
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Receiver Operating Characteristic Plot
Errors occurring during blood pressure monitoring
Several factors...