Related Experiment Video
Updated: Dec 21, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Respiratory activity extracted from wrist-worn reflective photoplethysmography in a sleep-disordered population
Gabriele B Papini1,2,3, Pedro Fonseca1,2, Merel M van Gilst1,3
1Department of Electrical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven, The Netherlands.
Objective:
Respiratory activity is an essential parameter to monitor healthy and disordered sleep, and unobtrusive measurement methods have important clinical applications in diagnostics of sleep-related breathing disorders. We propose a respiratory activity surrogate extracted from wrist-worn reflective photoplethysmography validated on a heterogeneous dataset of 389 sleep recordings.
Approach:
The surrogate was extracted by interpolating the amplitude of the PPG pulses after evaluation of pulse morphological quality. Subsequent multistep post-processing was applied to remove parts of the surrogate with low quality and high motion levels. In addition to standard respiration rate performance, we evaluated the similarity between surrogate respiratory activity and reference inductance plethysmography of the thorax, using Spearman's correlations and spectral coherence, and assessed the influence of PPG signal quality, motion levels, sleep stages and obstructive sleep apnea.
Main Results:
Prior to post-processing, the surrogate already had a strong similarity with the reference (correlation = 0.54, coherence = 0.81), and reached respiration rate estimation performance in line with the literature (estimation error = 0.76± 2.11 breaths/min). Detrimental effects of low PPG quality, high motion levels and sleep-dependent physiological phenomena were significantly mitigated by the proposed post-processing steps (correlation = 0.62, coherence = 0.88, estimation error = 0.53± 1.85 breaths/min).
Significance:
Wrist-worn PPG can be used to extract respiratory activity, thus allowing respiration monitoring in real-world sleep medicine applications using (consumer) wearable devices.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I
Acute Respiratory Failure-IV
Sleep-Wake Cycles
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge: