The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Customised three-dimensional printed revision acetabular implant for large defect after failed triflange revision cup
Stefano Zanasi1,2, Hassan Zmerly3,4
1Hesperia Hospital, Modena, Emilia-Romagna, Italy.
Abstract:
Aseptic loosening is the most common cause for total hip arthroplasty revision. Acetabular cup revision is a significant challenge in the presence of a large bone defect. One of the options for cup revision in the presence of a large bone defect is the recently introduced customised three-dimensional (3D)-printed reconstruction. We present the case of a 68-year-old woman successfully treated with a customised revision acetabular implant for the failure of triflange cup in the presence of large acetabular defect. The modern orthopaedic surgeon must have full knowledge of customised 3D-printed reconstruction to have as a reserve solution for difficult hip revision surgery.