Performance Problems of Non-Toroidal Shaped Current Transformers

Carlos A Platero1, José Ángel Sánchez-Fernández2, Konstantinos N Gyftakis3

  • 1Department of Automatic Control, Electrical and Electronic Engineering and Industrial Informatics, Universidad Politécnica de Madrid, E-28006 Madrid, Spain.

Related Concept Videos

Instrument Transformers01:23

Instrument Transformers

Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
378
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
1.3K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.2K
Transformers with Off-Nominal Turns Ratios01:25

Transformers with Off-Nominal Turns Ratios

In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
446
Toroids01:27

Toroids

A toroid is a closely wound donut-shaped coil constructed using a single  conducting wire. In general, it is assumed that a toriod consists of  multiple circular loops perpendicular to its axis.
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb points in...
3.7K
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
5.6K