A Novel and Practical Method of Performing Atrioventricular Nodal Ablation via a Superior Approach in Patients with
Helbert Acosta1,2, Lina M Viafara1, Nayyab Hanif1
1Trinity Medical Center, Rock Island, IL, USA.
Abstract:
Atrioventricular node (AVN) ablation is a strategy to manage patients with drug-refractory atrial fibrillation (AF) and heart failure in whom cardiac resynchronization therapy (CRT) device implantation has been prescribed. This study describes a practical method to perform these two procedures using the same surgical site. Twenty-seven patients were indicated for AVN ablation and concurrent CRT device implantation while presenting with AF and rapid ventricular response (RVR) refractory to medical therapy. After placement of the right and left ventricular leads, a third puncture was made in the axillary vein to obtain access to perform the ablation. After hand-injecting contrast media through a RAMP™ (Abbott Laboratories, Chicago, IL, USA) sheath positioned in the right atrial cavity, the anatomical area corresponding to the AVN was identified using fluoroscopy cine runs obtained in the right anterior oblique and left anterior oblique projections. The adequate site for ablation was confirmed by the bipolar recording of a His-bundle deflection at the tip of the ablation catheter. Radiofrequency energy was delivered to achieve complete heart block. Subsequently, device implant was completed. The method was successfully applied in 27 consecutive cases, achieving permanent complete heart block in all patients. The mean radiofrequency time to achieve heart block was 110 seconds ± 43 seconds. The average procedural time including AVN ablation and device implant was 87 minutes ± 21 minutes. The images obtained with the hand-injected contrast media provided adequate information to readily identify the anatomical area corresponding to the AVN with 100% accuracy. This study suggests that ablation of the AVN can be safely and effectively accomplished via a superior approach in patients undergoing a CRT device implant.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013