Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Characterization of the PTW-34089 type 147 mm diameter large-area ionization chamber for use in light-ion beams
Peter Kuess1, Sarah Haupt1, Jhonnatan Osorio2
1Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria.
Abstract:
A newly-designed large-area plane-parallel ionization chamber (of type PTW 34089), denoted BPC150, with a nominal active volume diameter of 147 mm is characterized in this study. Such chambers exhibit benefits compared to smaller chambers in the field of scanned light-ion beam dosimetry because they capture a larger fraction of the laterally-spread beam fragments and ease positioning with respect to small fields. The chamber was characterized in 60Co, 200 kV x-ray, proton and carbon ion beams. The chamber-specific beam-quality correction factor kQ,Q0 was determined. To investigate the homogeneity of the chamber's response, a radial response map was acquired. An edge correction was applied when the proton beam only partly impinged on the chamber's active surface. The measured response map showed that the response in the chamber's center is 3% lower than the average response over the total active area. Furthermore, percentage depth dose (PDD) curves in carbon ions were acquired and compared to those obtained with smaller-diameter chambers (i.e. 81.6 mm and 39.6 mm) as well as with results from Monte Carlo simulations. The measured absorbed dose to water cross calibration coefficients resulted in a kQ,Q0 of 0.981 ± 0.020. Regarding carbon ion PDD curves, relative differences between the BPC150 and smaller chambers were observed, especially for higher energies and in the fragmentation tail. These differences reached 10%-22% in the fragmentation tail (compared to the 81.6 mm diameter chamber). Differences increased when comparing to a chamber with 39.6 mm diameter. The provided results characterize the BPC150 thoroughly for usage in scanned light-ion beam dosimetry and demonstrate its advantage of capturing a larger fraction of the laterally-integrated dose in the fragmentation tail.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Analyzers: Common Types
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...