Related Experiment Video
Updated: Dec 20, 2025

Data Communication Based on MQTT in a Polymer Extrusion Process
Published on: July 15, 2022
Performance of LoRaWAN for Handling Telemetry and Alarm Messages in Industrial Applications
Francisco Helder C Dos Santos Filho1,2, Plínio S Dester2, Elvis M G Stancanelli1
1Federal University of Ceará, Quixadá 63902-580, Brazil.
Abstract:
This paper analyzes the feasibility of the coexistence of telemetry and alarm messages employing Long-Range Wide-Area Network (LoRaWAN) technology in industrial environments. The regular telemetry messages come from periodic measurements from the majority of sensors while the alarm messages come from sensors whose transmissions are triggered by rarer (random) events that require highly reliable communication. To reach such a strict requirement, we propose here strategies of allocation of spreading factor, by treating alarm and regular (telemetry) messages differently. The potential of such allocation strategies has also been investigated under retransmission and diversity of gateways. Both indoor industrial plant and open-field scenarios are investigated. We compare the proposed solution with a benchmark scenario-where no alarm is considered-by using system level simulation. Our results show that it is possible to achieve high reliability with reasonably low delay for the alarm messages without significantly affecting the performance of the regular links.
More Related Videos
04:13Using a Real-Time Locating System to Measure Walking Activity Associated with Wandering Behaviors Among Institutionalized Older Adults
Published on: February 8, 2019
08:49Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Related Concept Videos
Operational Amplifiers
Pilot and Numeric Relaying
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Transmission Line Design Considerations
Differential Relays
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...