LC-Swan Probe: An Integrated In Situ Sampling Interface for Liquid Chromatography Separation and Mass Spectrometry
Di-Qiong Jin1, Shao-Wen Shi1, Yan Ma1
1Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, P. R. China.
Abstract:
In situ sampling mass spectrometry (MS) systems can achieve rapid analysis of samples, while most of them do not have the pretreatment capability of chromatographic separation. This Article describes the design, fabrication, and application of a swan-shaped in situ sampling MS probe with liquid chromatography (LC) separation capacity. The LC-Swan probe was fabricated based on a single capillary with a micrometer-sized hole at its U-shaped bottom for sampling, a monolithic column for separation, and a tapered tip for electrospray. Four functions including in situ sampling, sample injection, chromatographic separation, and MS electrospray were integrated in the LC-Swan probe. Direct sampling and contacting-dissolution-injection sampling modes were developed to perform in situ sampling and injection of liquid samples and dry spot samples, respectively, in the high flow-resistance LC system. A pressing-sealing method was also developed using a polydimethylsiloxane (PDMS) sealer to achieve the sealing of the probe sampling hole during the high-pressure chromatographic separation process. The LC-Swan probe-based system exhibited effective desalting capacity in the analysis of angiotensin II with similar relative standard deviations (RSDs) of retention time and peak area below 3% and 19% (n = 3) for both salt-containing and salt-free samples. The present system was applied for analyzing cytochrome C digest to test its separation capability for samples with complex compositions, and 19 peptides were detected in 13 min with an amino acid coverage of 85%. We also applied the system in metabolite analysis of mouse organ sections of brain, liver, and kidney to preliminarily demonstrate its application potential in MS imaging analysis.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
08:53Quantitative and Qualitative Method for Sphingomyelin by LC-MS Using Two Stable Isotopically Labeled Sphingomyelin Species
Published on: May 7, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....