Diaphyseal Screw Prominence in Distal Radius Volar Plating
Kevin Eng1,2, Stephen Gil1,2, Richard Page1,2
1Barwon Health, Deakin University Geelong, Geelong, Australia.
Abstract:
Background Volar plating for distal radius fractures has become common. Screw prominence on the dorsal side from long screws can lead to tendon injury. Methods for detecting screws that penetrate the far cortex involve X-ray or ultrasound. These have focused on the distal row of screws. No studies have addressed screw penetration in the diaphysis. We describe two cases where diaphyseal screws caused symptoms. We then insert screws in the diaphysis of synbones 2 mm longer than measured and determine what angle of pronation or supination was best to detect this on X-ray. Methods Three synbones were plated using Synthes volar plate. The three diaphyseal screws were drilled perpendicular to the plate, and the depth measured. Cortical 2.4-mm screws were inserted, 2 mm longer than measured. The three synbones were then placed in a custom clamp to measure rotation. Lateral X-rays were taken at 0 degree rotation, and 5, 10, and 15 degrees of supination and pronation. The prominence of each screw was measured using the synapse digital ruler. Results For the screws that were placed at a neutral angle (perpendicular to the plate) the maximum visualization of the prominent tips occurred around 0 degree rotation. With screws angled 15 degrees ulna, maximum visualization was between 5 and 10 degrees of pronation. With screws angled 15 degrees radial, maximum visualization was between 5 and 10 degrees of supination. Every 5 degrees of rotation changes the profile of the screw by 0.4 mm. Discussion The diaphysis of the radius becomes approximately trapezoidal distally. Prominent screws that are placed below the "peak" of the trapezoid may appear to be the correct length. Rotating the wrist into pronation or supination to bring the relevant cortex as parallel to the X-ray beam as possible will help to identify if screws are of the correct length. Screws that are prominent in the second compartment may be particularly symptomatic as the tendons here are closely opposed to the bone. We recommend screening for 2 mm diaphyseal screw prominence in neutral, with 10 degrees of pronation and supination.
More Related Videos
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
09:26An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur
Published on: October 23, 2017
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Humerus
Bones of the Lower Limb: Tibia and Fibula
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...