Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Assessing Baveno VI criteria with liver stiffness measured using a new point-shear wave elastography technique
Matteo Garcovich1, Enrico Di Stasio1,2, Maria A Zocco1
1Department of Internal Medicine, Gastroenterology and Liver Diseases, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
Background And Aims:
To date, no study has explored the potential role of ElastPQ, a novel point-SWE technique, in the assessment of clinically significant portal hypertension. The aim of our study was to determine a liver stiffness (LS) cut-off value measured by ElastPQ and laboratory parameters that could help to identify those patients who can safely avoid screening endoscopy.
Methods:
Data were collected on 1422 patients who underwent ElastPQ measurement from January 2013 to January 2016 in our Department. Inclusion criteria were a LS value of ≥7 kPa, an upper gastrointestinal endoscopy within 12 months and a diagnosis of compensated chronic liver disease. Exclusion criteria were history of decompensated liver disease, evidence of porto-spleno-mesenteric vein thrombosis and non-cirrhotic portal hypertension. Varices were graded as low-risk varices (grade <2) or varices needing treatment (VNT, grade ≥2).
Results:
The study included 195 patients (120 [61%] HCV, 171 [88%] Child-Pugh A). Varices were present in 35% cases, with 10% prevalence of VNT. According to ROC curve analysis, LS measurement and platelet count were evaluated as predictors of VNT. Overall, 75/195 (38%) met the 'BAVElastPQ' criteria (that is, LS < 12 kPa and platelet count >150 000/μL). Within this group, 11/75 (15%) had any grade of varices and only 1/75 (1%) had VNT. The BAVElastPQ criteria gave sensitivity of 0.95, specificity of 0.42, positive predictive value of 0.15 and negative predictive value of 0.99.
Conclusions:
The BAVElastPQ criteria correctly identified 99% of patients without VNT. By applying such criteria, we could have potentially avoided 38% of surveillance endoscopies in our cohort.
More Related Videos
10:10Measurement of Liver Stiffness Using Atomic Force Microscopy Coupled with Polarization Microscopy
Published on: July 20, 2022
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...