Reliability of the international spinal cord injury urodynamic basic data set version 1.0
Kittamet Dejkriengkraikul1,2, Sintip Pattanakuhar1, Tuankasfee Hama1,3
1Department of Rehabilitation Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Spinal Cord
|June 10, 2020
Summary
The International Spinal Cord Injury (SCI) Urodynamic Basic Data Set (UBS) shows good reliability for most items in assessing urodynamic function in SCI patients. However, bladder compliance and urethral function require further refinement.
Area of Science:
- Urology
- Nephrology
- Rehabilitation Medicine
Background:
- Urodynamic assessment is crucial for managing neurogenic bladder in spinal cord injury (SCI).
- Standardized data collection tools are needed to improve the consistency and reliability of urodynamic evaluations in SCI.
- The International SCI Urodynamic Basic Data Set (UBS) was developed to standardize this process.
Purpose of the Study:
- To evaluate the interrater and intrarater reliability of version 1.0 of the International SCI Urodynamic Basic Data Set (UBS).
- To determine the clinical utility of the UBS for urodynamic assessment in individuals with SCI.
Main Methods:
- A cross-sectional study was conducted at a urodynamic clinic.
- Two independent raters analyzed urodynamic tracings from 50 SCI patients.
- Each rater completed the UBS twice, with a 1-month interval between assessments, to assess intrarater reliability.
- Interrater and intrarater reliability were analyzed using Kappa, Weighted Kappa, and Intraclass Correlation Coefficient (ICC).
Main Results:
- Interrater reliability for most UBS items was substantial to almost perfect (0.78-0.99).
- Intrarater reliability ranged from fair to almost perfect for the first rater (0.37-1.00) and moderate to almost perfect for the second rater (0.51-1.00).
- Lower reliability was noted for bladder compliance and urethral function items.
Conclusions:
- The International SCI Urodynamic Basic Data Set (UBS) version 1.0 demonstrates acceptable interrater and intrarater reliability for most items.
- While bladder compliance and urethral function showed lower reliability, these have been addressed in subsequent versions.
- The UBS is considered clinically useful for urodynamic assessment in SCI patients due to its simplicity and reliability.