Performance of peripheral arterial tonometry-based testing for the diagnosis of obstructive sleep apnea in a large
Octavian C Ioachimescu1,2, J Shirine Allam1,2, Arash Samarghandi1
1Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, Emory University School of Medicine, Atlanta, Georgia.
Study Objectives:
Peripheral arterial tonometry (PAT)-based technology represents a validated portable monitoring modality for the diagnosis of OSA. We assessed the diagnostic accuracy of PAT-based technology in a large point-of-care cohort of patients studied with concurrent polysomnography (PSG).
Methods:
During study enrollment, all participants suspected to have OSA and tested by in-laboratory PSG underwent concurrent PAT device recordings.
Results:
Five hundred concomitant PSG and WatchPat tests were analyzed. Median (interquartile range) PSG AHI was 18 (8-37) events/h and PAT AHI3% was 25 (12-46) events/h. Average bias was + 4 events/h. Diagnostic concordance was found in 42%, 41%, and 83% of mild, moderate, and severe OSA, respectively (accuracy = 53%). Among patients with PAT diagnoses of moderate or severe OSA, 5% did not have OSA and 19% had mild OSA; in those with mild OSA, PSG showed moderate or severe disease in 20% and no OSA in 30% of patients (accuracy = 69%). On average, using a 3% desaturation threshold, WatchPat overestimated disease prevalence and severity (mean + 4 events/h) and the 4% threshold underestimated disease prevalence and severity by -6 events/h.
Conclusions:
Although there was an overall tendency to overestimate the severity of OSA, a significant percentage of patients had clinically relevant misclassifications. As such, we recommend that patients without OSA or with mild disease assessed by PAT undergo repeat in-laboratory PSG. Optimized clinical pathways are urgently needed to minimize therapeutic decisions instituted in the presence of diagnostic uncertainty.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.