Related Experiment Video
Updated: Dec 18, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Assessment of exercise-induced changes in von Willebrand factor as a marker of severity of aortic stenosis
Jo M Zelis1, Frederik M Zimmermann1, Froukje P J Andriessen1
1Cardiology, Catharina Hospital, Eindhoven, The Netherlands.
Background:
Loss of high-molecular-weight multimers (HMWMs) of von Willebrand factor (vWF) occurs due to high shear stress in patients with aortic stenosis. As symptoms of aortic stenosis occur during exercise, measurement of vWF during exercise might identify patients with aortic stenosis of clinical importance. The aim of this pilot study is to evaluate whether vWF changes over time as a result of exercise in patients with asymptomatic moderate or severe aortic stenosis.
Methods:
Ten subjects were analysed for changes in vWF by measuring HMWMs and closure time with adenosine diphosphate (CT-ADP). All subjects underwent a full stress test on a bicycle ergometer. At rest and at peak exercise, a transthoracic echocardiogram was performed. HMWMs and CT-ADP were assessed at baseline, during and after exercise.
Results:
HMWMs and CT-ADP did not change significantly during exercise, p=0.45 and p=0.65, respectively. HMWMs and CT-ADP correlated well, Spearman's rho -0.621, p<0.001. HMWMs during peak exercise did not correlate with maximal velocity measured, p=0.21. CT-ADP during exercise correlated well with the maximal echocardiographic velocity over the aortic valve (AV), rho 0.82, p=0.04.
Conclusions:
In a cohort of 10 patients with moderate or severe aortic stenosis, we observed no significant change in vWF biomarkers during exercise. Peak CT-ADP during exercise showed a good correlation with peak AV velocity measured with echo. Although CT-ADP is an easy test to perform and could be an alternative for peak AV velocity measured during exercise, our results suggest that it can only detect large changes in shear stress.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies