Concordance of the ACR TI-RADS
C M González Vásquez1, J A Muñoz Durán2, S Isaza Zapata2
1Radiólogo, Hospital Pablo Tobón Uribe, Antioquia, Colombia.
Background:
Ultrasonography (US) is the method of choice for evaluating thyroid nodules. In 2017, the American College of Radiology (ACR) created a classification system based on US characteristics. For the system to be adopted, it must be reproducible.
Objectives:
To determine the intraobserver and interobserver variability of the ACR TI-RADS.
Methods:
Cross-sectional study; three radiologists with different levels of experience used the ACR TI-RADS to classify 100 nodules on two occasions one month apart, and we calculated the intraobserver and interobserver variability.
Results:
Regarding intraobserver variability, the first radiologist had nearly perfect concordance for composition, echogenicity, shape, and margins and substantial concordance for echogenic foci; the second radiologist had nearly perfect concordance for composition, echogenicity, shape, and margins and substantial concordance for echogenic foci, and the third radiologist had nearly perfect concordance for composition, echogenicity, and shape and substantial concordance for margins and echogenic foci. The interobserver concordance was calculated for the two readings; the concordance was substantial except for shape in the first reading and for echogenicity and margins in the second reading, which had moderate concordance.
Conclusions:
The ACR TI-RADS classification system is reproducible.
More Related Videos
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Radicals: Electronic Structure and Geometry
Accordingly, the structure of a trivalent radical lies between the geometries of carbocations and carbanions. An sp2-hybridized carbocation is trigonal planar, while an sp3-hybridized carbanion is trigonal pyramidal. Here, the difference in geometry is...