Quantitative evaluation of the effect of changes in effective energy on the image quality in X-ray computed
Ayana Ishiguro1, Kazuhiro Sato2, Masaaki Taura3
1Sendai Open Hospital, 5-22-1 Tsurugaya, Miyagino-ku, Sendai, Miyagi, 983-0824, Japan. ayn.0302@icloud.com.
Abstract:
The X-ray effective energy differs for each computed tomography (CT) scanner even at the same tube voltage because of differences in the bow-tie filter and additional filter. Even when scanning with the same tube voltage and dose setting, these differences in effective energy result in different image noise levels. Although this qualitative change is known, the related quantitative changes have not been clarified. In this study, using two CT scanners with the same geometric specifications and detector configurations, we quantitatively assessed the reduction in image noise accompanying the increase in effective energy. We also clarified the fluctuations in CT number. For both CT scanners, the effective energy, the standard deviation (SD) of the noise image when using two water phantoms with diameters of 240 mm and 320 mm, and CT numbers of the sensitometry module were measured. Further, the dose required to obtain the same image noise level in each CT scanner was calculated. The effective energy difference was 5.5 keV to 10.7 keV, and the difference tended to be larger when the scan field of view was larger. The SD differences were 24% and 14% for the 320-mm and 240-mm phantoms, respectively. For converting to the dose required to obtain the same SD, the dose can be reduced by 42% and 24% for the 320-mm and 240-mm phantoms, respectively. The CT number difference of both CT scanners was small. Therefore, higher effective energy contributes to the reduction of image noise.
More Related Videos
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...