Validation of Rapid Enzymatic Quantification of Acetic Acid in Vinegar on Automated Spectrophotometric System

Irene Dini1, Ritamaria Di Lorenzo1, Antonello Senatore2

  • 1Department of Pharmacy, University of Naples Federico II, Via Domenico Montesano 49, 80131 Napoli, Italy.

Related Concept Videos

Titration of a Weak Acid with a Strong Base01:30

Titration of a Weak Acid with a Strong Base

In titrating a weak acid with a strong base, different calculation methods are applied at various stages. Initially, the pH of a weak acid like acetic acid is calculated using its dissociation constant (Ka) and an ICE table. Upon addition of a strong base such as sodium hydroxide, a buffer forms, and its pH is determined using the Henderson-Hasselbalch equation. As more base is added and the titration reaches the halfway point, the pH becomes equal to the pKa of the acid, indicating equal...
4.2K
Solution Composition During Acid/Base Titrations01:17

Solution Composition During Acid/Base Titrations

The titration of a weak acid with a strong base results in the formation of water and the conjugate base of the acid. For instance, titrating acetic acid with sodium hydroxide leads to the formation of water and sodium acetate. A solution of acetic acid and sodium acetate constitutes a buffer whose relative concentration at different stages of the titration is indicated by the α values, which represent percentages of the weak acid and its conjugate base.
The α0 and α1 values...
1.5K
Titration of a Weak Acid with a Weak Base01:08

Titration of a Weak Acid with a Weak Base

Weak acids and bases do not undergo dissociation completely, and titrations between these two are rarely studied. When such studies are performed, say, for the titration of a weak acid with a weak base, the titration curve plots the change in pH as a function of the volume of base added. Take the titration of acetic acid with ammonia, for instance. During the titration, these two species form ammonium acetate and water, but the pH change is slow and gradual.
As a result, there is no simple...
4.6K
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
48.7K
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
1.6K
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
5.5K