Related Experiment Video
Updated: Dec 18, 2025

Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
Functional joint center of prosthetic feet during level ground and incline walking
Christophe Lecomte1, Felix Starker2, Elísabet Þ Guðnadóttir3
1Össur hf., Grjóthálsi 5, 110 Reykjavik, Iceland; Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, School of Engineering and Natural Sciences, University of Iceland, Reykjavík, Iceland.
Abstract:
Energy storage and returning prosthetic feet do not provide a well-defined articulation point compared to the human ankle. Calculation of user relevant parameters, such as ankle power, requires such a joint center point when using traditional mechanical models. However, shortcomings of current calculation methods result in some errors. The aim of this case study was to compare conventional ankle joint calculations to a functional joint center (FJC) using data collected on a roll-over test machine and in a motion lab during dissimilar walking tasks. Three prosthetic feet were evaluated on a roll-over test machine. Then, two trans-tibial amputees were each fitted with the same three prosthetic feet matching their weight and activity category. Kinematic data were collected during walking on level ground, as well as up and down a slope. The FJC during the stance phase of gait was calculated for each test method and compared with outcomes using conventional methods. The location of the FJC was generally anterior and inferior to the estimated anatomical joint position. Importantly, the FJC location varied for the different prosthetic feet and was task dependent as per the three gait conditions. This was reflected in different ankle angles and moments of FJC calculations compared to conventional methods for level ground walking. Differences in the calculated FJC between conditions represented the variations in prosthetic foot deformation, and explained how this parameter is influenced by the prosthetic's stiffness. For level ground walking, calculated FJC location between human subject testing and machine evaluation were strongly correlated. Both stiffness and task dependent demands of the prosthetic foot should be considered during testing. The FJC of elastic ankles can serve as a parameter for characterization and differentiation between various prosthetic foot designs and be an important parameter for prosthetic foot designers to consider. As the position of the FJC is dependent on the design and task, it is a more informative measure of the prosthetic foot's response to the user's needs. Furthermore, prosthetists could use this metric in clinical practice to better appreciate amputee feedback and perception. FJC provides an alternative center during calculation of ankle power using standard methods.
Related Concept Videos
Ankle Joint
Muscles of the Leg that Move the Foot and Toes
Anterior Compartment
The anterior compartment includes muscles that contribute to the dorsiflexion of the foot. This compartment houses the tibialis anterior, extensor hallucis longus, and extensor digitorum longus muscles....
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bones of the Lower Limb: Tibia and Fibula
Bones of the Lower Limb: Femur and Patella
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...