Background:
Reduced coronary flow reserve in aortic stenosis and after transcatheter aortic valve implantation is usually attributed to physiological factors taking place during systole, such as an increase in coronary resistance, and backward waves intensity. In this paper, we suggest an additional factor related to the diastolic hemodynamics in the aortic root.
Methods:
We measured left ventricle, aortic and coronary pressure and coronary perfusion in in-vitro models of healthy, aortic stenosis and an artificial valve at different heart rates and cardiac output conditions, to isolate the effect of hemodynamic factors in the aortic root during diastole.
Findings:
Our results show that during diastole, coronary perfusion depends on the pressure gradient between the aorta and the coronary inlet. This aorta-coronary pressure gradient is influenced by the hemodynamic flow field in the aortic root. The ratio between the aorta-coronary pressure gradient magnitude in stress to that under rest conditions of a healthy model is ten times higher than the same ratio in the aortic stenosis model and twice higher as compared to the artificial valve model result. The coronary flow reserve of the healthy model is correspondingly higher compared to the artificial valve and the aortic stenosis models. These results are in agreement with the clinical evidence.
Interpretation:
This study supports the hypothesis of a hemodynamic mechanism in the aortic root that increases coronary flow during rest but reduces the coronary flow reserve in aortic stenosis and artificial valve cases. The results may provide valuable insights regarding valve design.
More Related Videos
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
06:22Author Spotlight: Advancing Cardiovascular Research — Tailored Langendorff Perfusion Techniques for Improved Experimental Outcomes
Published on: June 14, 2024
Related Concept Videos
Pathophysiology of Cardiac Performance
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests