Related Experiment Video
Updated: Dec 18, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results
Ruth Lapid-Gortzak1, Uday Bhatt, Juan Gonzalo Sanchez
1From the Department of Ophthalmology, Amsterdam University Medical Centers (Lapid-Gortzak), Amsterdam, Netherlands; Vision Eye Institute (Bhatt), Melbourne, Victoria, Australia; Instituto Nacional de Investigacion en Oftalmologia (Sanchez), Medellin-Antioquia, Colombia; Valles Oftalmologia Recerca (Guarro), Barcelona, Spain; Hospital Oftalmologico de Brasilia (Hida), Brasilia, Brazil; Personal Eyes (Bala), Sydney, New South Wales, Australia; Eye Clinic (Nosé), São Paulo, Brazil; Fundacion Oftalmologica Nacional, Universidad del Rosario (Alvira), Bogota, Colombia; Alcon Vision LLC (Martinez), Fort Worth, Texas, USA.
Purpose:
To clinically evaluate visual performance of the AcrySof IQ PanOptix TFNT00 and AT LISA tri 839MP intraocular lenses (IOLs) in binocular visual acuity (VA) and to characterize low-contrast visual performance at 6 months postimplantation.
Setting:
Multicenter, 15 sites.
Design:
Prospective, parallel-group, randomized, double-masked, postmarketing clinical study.
Methods:
Binocular uncorrected distance (UDVA, 4 m), intermediate (UIVA, 60 cm), and near (UNVA, 40 cm) visual acuities and binocular defocus curves were evaluated under photopic lighting conditions. Photopic and mesopic contrast sensitivities with and without glare were assessed.
Results:
The study included 182 subjects (62% women; mean age, 66 ± 9.4 years) who were implanted bilaterally with the TFNT00 IOL (n = 93) or 839MP IOL (n = 89), and binocular VA was evaluated 4 to 6 months (120-180 days) postimplantation. The TFNT00 IOL group showed superior visual outcomes compared with the 839MP IOL group in binocular UIVA (P = .001) and UNVA (P = .003) and noninferior outcomes in UDVA (95% CI, -0.023 to 0.041; upper limit <0.1 logarithm of the minimum angle of resolution [logMAR] [margin of noninferiority]). Mean defocus curve from 0.00 to -3.00 diopter (D) ranged from 0.1 to 0.0 logMAR for both IOLs; better mean VA values (logMAR) were observed in the TFNT00 IOL group between -1.50 and -2.50 D compared with those of the 839MP IOL group. Contrast sensitivity values were similar between the 2 groups in all conditions.
Conclusions:
The results of this study showed improved visual performance at near and intermediate distances with the TFNT00 IOL compared with that of the 839MP IOL.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...