Related Experiment Video
Updated: Dec 18, 2025

Fabricating a Kidney Cortex Extracellular Matrix-Derived Hydrogel
Published on: October 13, 2018
Fabrication of Corneal Extracellular Matrix-Derived Hydrogels
Mark Ahearne1,2, Julia Fernández-Pérez3,4
1Department of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, The University of Dublin, Dublin, Ireland. ahearnm@tcd.ie.
Abstract:
Hydrogels derived from corneal extracellular matrix (ECM) represent a promising biomaterial for corneal repair and regeneration. To fabricate these hydrogels, first corneas need to be decellularized using repeated freeze-thaw cycles and nucleases to remove all nuclear and cellular components. The remaining corneal ECM is lyophilized to remove all water and milled into a fine powder. The ECM powder is weighed and dissolved in pepsin solution at a concentration of 20 mg/mL. Hydrogels are formed by neutralizing the pH of the solution and maintaining it at 37 °C until fibrillogenesis has occurred. Corneal stromal cells may be suspended throughout the hydrogel solution prior to gelation to generate a corneal stromal substitute.