Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Electron Ionization Mass Spectrometry for Both Liquid and Gas Chromatography in One System without the Need for
Svetlana Tsizin1, Alexander B Fialkov1, Aviv Amirav1
1School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel.
Abstract:
A new instrument that bridges the gap between gas chromatography (GC) and liquid chromatography (LC) mass spectrometry (MS) was developed. In this instrument GC-MS and electron ionization LC-MS were combined in one MS system with method based mode changing. The LC pneumatic spray formation interface to MS was mounted on top of an otherwise unused GC detector slot and was connected with a flow restriction capillary to the MS through the GC oven and into the MS transfer line, parallel to the GC capillary column. The LC output mobile phase flow is directed into a spray formation and vaporization chamber. The pneumatic spray results in fine spray droplets that are thermally vaporized at a pressure equal to or greater than ambient. A portion of the vaporized mixture is directed into the heated flow restriction capillary that connects the spray formation and vaporization chamber into the electron ionization (EI) ion source, while most of the vaporized spray is released to the atmosphere. The combined GC-MS and LC-MS system can work either with standard EI or with cold EI via interfacing the flow restriction capillary into a supersonic nozzle forming a supersonic molecular beam of a vibrationally cold sample compound. We found that EI-LC-MS with cold EI has many benefits when compared with standard EI. The EI-LC-MS interface can also serve for flow injection analysis. The performance of the combined system is demonstrated in the analysis of a few sample mixtures by both GC-MS and LC-MS analysis, sequentially without hardware adjustments.
More Related Videos
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometers
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview