Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Cold EI-The Way to Improve GC-MS and Increase Its Range of Applications
Aviv Amirav1,2, Benny Neumark1, Oneg Elkabets1
1School of Chemistry, Tel Aviv University, Tel Aviv, Israel.
None:
Gas chromatography-mass spectrometry (GC-MS) with Cold electron ionization (EI) is based on interfacing the GC and MS with a supersonic molecular beam (SMB) along with electron ionization of vibrationally cold sample compounds in the SMB in a contact-free fly-through ion source (hence the name Cold EI). Cold EI improves all the central performance aspects of GC-MS, including: a significantly extended range of compounds that are amenable for analysis, enhanced molecular ions, highly improved sample identification, faster analysis (much faster), uniform response to all analytes, greater selectivity and higher signal to noise ratios and lower limits of detection, particularly for compounds that are difficult to analyze. GC-MS with Cold EI executes the analysis of the full range of standard EI applications and most with major improvements of various metrics. Furthermore, it significantly extends the range of compounds and applications amenable for GC-MS analysis. Accordingly, it is a highly superior replacement ion source. In this review article, we describe Cold EI and its main features, discuss its benefits, and demonstrate several of its unique applications including cannabinoids analysis, synthetic organic compounds analysis, whole blood analysis for medical diagnostics, isomer distribution analysis for improved fuels and oils, and explosives analysis.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...