Related Experiment Video
Updated: Dec 18, 2025

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
The retinal venous pressure at different levels of airway pressure
Sofie Heimann1, Richard Stodtmeister2, Lutz E Pillunat2
1Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany. sofie.heimann@googlemail.com.
Purpose:
To investigate retinal venous pressure (RVP) as a function of airway pressure (AirP) during the Valsalva maneuver (VM) in human subjects.
Methods:
Forty-three healthy volunteers (age, 22.0 (2.3) years) (median and interquartile range) were investigated using the following instruments: dynamic contour tonometer, contact lens dynamometer (CLD), and aneroid manometer. The following measurements were performed in their left eyes: tonometry and dynamometry during VM at different levels of airway pressure (AirP = 0, 10, 20, 30, and 40 mmHg).
Results:
The median RVP during spontaneous breathing (AirP = 0) was 19.7 (6.4) (median in mmHg (interquartile range)) and the intraocular pressure (IOP) in mydriasis was 16.3 (3.1) mmHg. Spontaneous pulsation occurred in 58.1% of the subjects. RVP increased nonlinearly. The coefficient of variation of four individual measurements of RVP at each pressure level averaged 8.1 (7.6) %. At different AirP levels of 10, 20, 30, and 40 mmHg, the following RVPs were measured: 29.6 (12.6); 34.2 (12.8); 38.0 (10.5); and 40.3 (11.0), respectively. The rise of RVP (Δ RVP) during VM was significantly higher than that of Δ IOP (p < 0.0001, Wilcoxon test). Δ RVP between 0 and 40 mmHg AirP was 20.6 mmHg and Δ IOP 1.5 mmHg. The steepest slope of the RVP/AirP curve was observed at the first step from 0 to 10 mmHg of AirP (∆ RVP = 9.9 mmHg).
Conclusion:
A nonlinear relationship between RVP and AirP was found during VM. Small rises in AirP increase the RVP and affect retinal circulation.
More Related Videos
09:04Epidural Intracranial Pressure Measurement in Rats Using a Fiber-optic Pressure Transducer
Published on: April 25, 2012
10:11Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
Published on: October 22, 2014
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...