Related Experiment Video
Updated: Dec 17, 2025

The Quantification of Injectability by Mechanical Testing
Published on: May 13, 2020
Thermal Injection Measurement (TIM) Adds Accuracy to Injections and Can Assess Cold Chain Management
Elizabeth A Gilliam1, Samuel M Zuber1, Tracy C Grikscheit1
1Developmental Biology and Regenerative Medicine Program, The Saban Research Institute at Children's Hospital Los Angeles, Los Angeles, California.
Background:
Inaccurate assessment of injected drug delivery may increase cost and morbidity or reduce efficacy. Yet currently most injections are evaluated solely by the formation of a visible wheal that might not truly estimate the actual area of effect. We hypothesized that thermal injection measurement (TIM) might verify appropriate temperature at the time of injection, as required for some temperature-sensitive vaccines and provide more accurate information about the area of delivery.
Methods:
0.1 mL of either iced (n = 11) or room temperature (n = 17) methylene blue solution was injected subcutaneously in mice under anesthesia and photos taken with an iPhone 7 built-in camera and Thermal Seek Camera phone plug-in. After 5 min, true values were determined at necropsy.
Results:
TIM was closer in value to the measured area at necropsy than the area of the visualized skin wheal at both ice temperature and room temperature. The difference between the true value and thermal area assessment of iced solution averaged 0.15 cm2 as compared with the difference between the true value and wheal size, which averaged 0.27 cm2 (P = 0.04). At room temperature, this was maintained for thermal and visible wheal differences, 0.23 cm2 and 0.65 cm2, respectively (P = 0.0006).
Conclusions:
TIM can assess temperature at the time of injection and is more accurate than visual inspection. TIM could be applied to colorless injections and areas that are hard to visualize such as scar. As a portable phone plug-in, it might be a useful adjunct to aid the evaluation of injected drug delivery including in resource-limited settings.
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...