Related Experiment Video
Updated: Dec 17, 2025

Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Comparison of multiple blood pressure frequency methods with optimum blood pressure measurement among Iranian
Alireza Mohammadi-Dolatabadi1, Mehrbod Vakhshoori1, Maryam Eghbali-Babadi2
1Heart Failure Research Center, Isfahan Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.
Background:
Proper blood pressure (BP) measurement frequency method is less evaluated to optimize hypertension (HTN) status among different nations due to cultural patience variations. The aim of this study was to compare the first (BP1), second (BP2), and the mean of first and second (BP1,2) and all the three (BP1,2,3) with the second and third BP measurements in Iranian individuals.
Materials And Methods:
This cross-sectional study was done on 2264 individuals aged 18 years or more living in Isfahan city, Iran. Their BPs were assessed from right arms by the standard tools and methods after 5 min of rest in a quiet room by a trained staff. The mean second and third readings were considered as reference, and the other aforementioned variables were compared with it.
Results:
The mean age of total population was 40.9 ± 16.1 years (males: 52%). Men had significant higher means of systolic BP (SBP) and diastolic BP (DBP) with any measurement frequency methods than women (P < 0.001 and P = 0.009). Considerable clinical significant (≥5 mmHg) ranges were mostly observed in BP1 compared with BP2,3. SBP2 and DBP2 indices showed insignificant differences compared with reference mean. Moreover, abnormal BP levels (≥140/90 mmHg) were mostly observed in terms of BP1 measurement with no remarkable variability in BP2 reading in comparison to the reference.
Conclusion:
Our considerable data suggested that BP2 could appropriately categorize BP status similar to BP2,3 and it may be rational for physicians considering this mean and excluding the first BP measurement as a sole criterion for HTN assessment in Iranian adults. Multiple researches are necessary quantifying appropriate frequencies of BP reading.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...