Data-driven fault detection of open circuits in multi-phase inverters based on current polarity using Auto-adaptive
Thanh-Hung Pham1, Sanda Lefteriu1, Eric Duviella1
1Institut Mines Telecom Lille Douai, IA, F-59508 Douai, France.
Abstract:
This paper proposes a data-driven method for the detection and isolation of open-circuit faults in multi-phase inverters using measurements of the motor currents. First, feature variables are formulated in terms of the averages of the phase currents and their absolute values. Next, by using an AUto-adaptive and Dynamical Clustering (AUDyC) based on Gaussian Mixture Models, feature data is clustered into different classes characterizing normal and faulty operation modes. Afterwards, these classes are used for deriving appropriate conditions for detecting and labelling faults. The proposed method requires minimal knowledge about the system operation. Furthermore, it allows us to update our knowledge of existing faults online, thus making it possible to detect unknown faults. Moreover, conditions are formulated to describe the influence of the method parameters on the detection time. Once parameters are tuned, the accuracy of the proposed method is illustrated on various experimental data sets, where single and double faults are detected with detection times in the order of the fundamental signal period.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Related Concept Videos
Power System Three-Phase Short Circuits
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Fault Types
For line-to-line faults occurring between phases B and C, the...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...