Related Experiment Video
Updated: Dec 17, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Patient exposure data and operator dose in coronary interventional procedures: Impact of body-mass index and
Federica Zanca1, Celine Collard2, Nicolas Alexandre3
1Palindromo Consulting, W. de Croylaan 51 3000 Leuven, Belgium.
Purpose:
The aim of this study was to assess patient exposure data and operator dose in coronary interventional procedures, when considering patient body-mass index and procedure complexity.
Methods:
Total air kerma area product (PKA), Air-Kerma (AK), Fluoroscopy time (FT), operator dose and patient body-mass index (BMI) from 97 patients' procedures (62 coronary angiography (CA) and 35 Percutaneous Coronary Intervention (PCI) were collected for one year. For PCI procedures, also the complexity index-CI was collected. Continuous variables for each of the 2 groups procedures (CA and PCI) were compared as medians with interquartile range and using Mann-Whitney U test. Multiple group data were compared using Kruskal-Wallis test (significance: p < 0.05).
Results:
Median PKA was 63 and 125 Gy cm2 for CA and PCI respectively (p < 0.001); FT was 3 and 14 min, respectively (p < 0.001). PKA and FT significantly increased (p < 0.05) with BMI class for CA procedures. PKA and FT also increased in function of CI class for PCI, thought significantly only for FT (p < 0.001), possibly because of the low number of PCI procedures included; cine mode contributed most to PKA. Significant dose variability was observed among cardiologists for CA procedures (p < 0.001).
Conclusions:
Dose references levels for PKA and FT in interventional cardiology should be defined - on a sufficient number of procedures- in function of CI and BMI classes. These could provide an additional tool for refining a facility's quality assurance and optimization processes. Dose variability associated with cardiologists underlines the importance of continuous training.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Drug Dosing: Obese Patients
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Dose-Response Relationship: Overview
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...