The Treatment Method and Results of Percutaneous Pinning and Dynamic External Fixator Application for Unstable Distal
Adnan Kara1, Erden Ertürer2, Faik Seçkin3
1Department of Orthopedics and Traumatology, Medipol University Faculty of Medicine, Istanbul, Turkey.
Objective:
The aim of the present study was to present the results of patients with unstable distal radius fracture treated with closed reduction and percutaneous fixation followed by application of the Pennig dynamic wrist fixator to allow early wrist motion.
Methods:
Twenty-five patients diagnosed with distal radius fracture and treated with closed reduction and percutaneous fixation followed by application of a dynamic wrist fixator were included in the study. There were 15 (60%) male and 10 (40%) female patients. The mean age of the patients was 47.32 (20-76) years. The mean period between initial trauma and operation was 8.52 (1-23) days. All patients were allowed active shoulder, elbow, and finger exercises immediately after surgery.
Results:
Radiological evaluation was performed according to the criteria described by Sarmiento and modified by Lidström. Results were excellent in 12 (46.15%), good in 11 (42.30%), and fair in 3 (11.55%) patients. No patient had poor result. Functional scores were assessed according to the Gartland-Werley classification and modified by Sarmiento. Results were excellent in 14 (56%), good in 8 (32%), and moderate in 3 (12%) patients.
Conclusion:
Use of the Pennig dynamic wrist fixator in the treatment of unstable distal radius fractures has advantages, such as ease of use, minimal surgical trauma, allowing early rehabilitation, and early return to daily activities as well as increased anatomical and functional results.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
06:59Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History: