Related Experiment Video
Updated: Dec 16, 2025

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
18F-Fluorocholine PET and Multiphase CT Integrated in Dual Modality PET/4D-CT for Preoperative Evaluation of Primary
Valentin Pretet1, Marianela Rotania1,2, Mehdi Helali1
1Nuclear Medicine and Molecular Imaging, ICANS-University Hospitals of Strasbourg, 67033 Strasbourg, France.
Abstract:
The present retrospective study evaluates the diagnostic value of integrated 18F-Fluorocholine positron emission tomography/four-dimensional contrast-enhanced computed tomography (18F-FCH PET/4D-CT) as second-line imaging in preoperative work-up of primary hyperparathyroidism (pHPT), and compares 18F-FCH PET with 4D-CT. Patients with pHPT and negative/discordant first-line imaging addressed for integrated 18F-FCH PET/4D-CT were retrospectively selected. Sensitivity and detection rate (DR%) of 18F-FCH PET/CT, 4D-CT, and PET/4D-CT were calculated according to the per patient and per lesion analyses, and afterwards compared. Histology associated with a decrease more than 50% of perioperative parathyroid hormone (PTH) blood level was used as a gold standard. Persistent high serum PTH and calcium levels during a 6-month follow-up was considered as presence of pHPT in both operated and non-operated patients. 50 patients (55 glands) were included. 44/50 patients (88%) were surgically treated. On a per patient analysis, sensitivity was 93%, 80%, and 95%, and DR% was 82%, 68%, and 84%, respectively for PET/CT, 4D-CT, and PET/4D-CT. PET/CT was more sensitive than 4D-CT (p = 0.046). PET/4D-CT performed better than 4D-CT (p = 0.013) but was equivalent to PET/CT alone. On a per gland analysis, sensitivity PET/CT, 4D-CT, and PET/4D-CT was 88%, 66%, and 92%, and DR% was 79%, 57%, and 83%, respectively. PET/CT and PET/4D-CT were more sensitive than 4D-CT alone (p = 0.01, p < 0.001, respectively). However, PET/CT and PET/4D-CT performed similarly. In conclusion, 18F-FCH PET provides better identification of hyperfunctioning parathyroids than 4D-CT and the combination of both did not significantly improve diagnostic sensitivity. Further investigations involving larger populations are necessary to define the role of 18F-FCH PET/4D-CT as a "one-stop shop" second-line imaging in preoperative work-up of pHPT, especially considering the additional patient radiation exposure due to multi-phase CT.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography