Related Experiment Video
Updated: Dec 16, 2025

Measurement of Coherence Decay in GaMnAs Using Femtosecond Four-wave Mixing
Published on: December 3, 2013
1/f2 spectra of decoherence noise on 75As nuclear spins in bulk GaAs
Susumu Sasaki1,2, Takanori Miura3, Kosuke Ikeda3
1Materials Science Program, Niigata University, Niigata, 950-2181, Japan. susumu@niigata-u.ac.jp.
Abstract:
To identify the decoherence origin, frequency spectra using multiple π-pulses have been extensively studied. However, little has been discussed on how to define the spectral intensities from multiple-echo decays and how to incorporate the Hahn-echo T2 in the noise spectra. Here, we show that experiments based on two theories solve these issues. As proved in the previous theory, the spectral intensity is given as the decay in the long-time limit. Unlike the initial process of decays, this definition is not only theoretically proven but also validated experimentally, since long-time behaviors are generally free from experimental artifacts. The other is the fluctuation-dissipation theory, with which the Hahn-echo T2 is utilized as the zero-frequency limit of the noise spectrum and as an answer to the divergent issue on the 1/fn noises. As a result, arsenic nuclear spins are found to exhibit 1/f2 dependences over two orders of magnitude in all the substrates of un-doped, Cr-doped semi-insulating and Si-doped metallic GaAs at 297 K. The 1/f2 dependence indicates that the noise is dominated by a single source with characteristic frequency fcun = 170 ± 10 Hz, fcCr = 210 ± 10 Hz and fcSi = 460 ± 30 Hz. These fc values are explained by a model that the decoherence is caused by the fluctuations of next-nearest-neighboring nuclear spins.
More Related Videos
12:57Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
Published on: October 13, 2017
08:42High-Sensitivity Nuclear Magnetic Resonance at Giga-Pascal Pressures: A New Tool for Probing Electronic and Chemical Properties of Condensed Matter under Extreme Conditions
Published on: October 10, 2014
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Atomic Nuclei: Nuclear Relaxation Processes
NMR Spectroscopy: Spin–Spin Coupling
Atomic Nuclei: Nuclear Spin State Population Distribution
NMR Spectrometers: Resolution and Error Correction